Open Access. Powered by Scholars. Published by Universities.®

Digital Commons Network

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 8 of 8

Full-Text Articles in Entire DC Network

Multi-Frequency Processing For Lumen Enhancement With Wideband Intravascular Ultrasound, Rory A. Carrillo Sep 2010

Multi-Frequency Processing For Lumen Enhancement With Wideband Intravascular Ultrasound, Rory A. Carrillo

Master's Theses

The application of high frequency ultrasound is the key to higher resolution intravascular ultrasound (IVUS) images. The need to further improve the IVUS spatial resolution may drive the transducer center frequency even higher than the current 40 MHz range. However, increasing the center frequency may be challenging as it leads to stronger scattering echoes from blood. The high level of blood scattering echoes may obscure the arterial lumen and make image interpretation difficult. Blood backscatter levels increase with transmission center frequency at a much greater rate compared to arterial tissue. These different frequency dependencies provide a potential method to distinguish …


St. Jude Medical: An Object-Oriented Software Architecture For Embedded And Real-Time Medical Devices, Atila Amiri Aug 2010

St. Jude Medical: An Object-Oriented Software Architecture For Embedded And Real-Time Medical Devices, Atila Amiri

Master's Theses

Medical devices used for surgical or therapeutic purposes require a high degree of safety and effectiveness. Software is critical component of many such medical devices. The software architecture of a system defines organizational structure and the runtime characteristic of the application used to control the operation of the system and provides a set of frameworks that are used to develop that. As such, the design of software architecture is a critical element in achieving the intended functionality, performance, and safety requirements of a medical device. This architecture uses object-oriented design techniques, which model the underlying system as a set of …


St. Jude Medical: Enhanced Mics (Emics), Devanshi Shah Aug 2010

St. Jude Medical: Enhanced Mics (Emics), Devanshi Shah

Master's Theses

Heart disease is one of the most prevalent diseases in the world. The survival chances for patients with ventricular fibrillation/ventricular tachycardia reduces significantly as time passes without treatment and even after getting timely treatment recurring episode are common. These patients can benefit from an Implantable Cardioverter Defibrillator (ICD) which can monitor heart rhythm and provide immediate treatment. Due to the ever changing physical conditions and disease progression, the ICD needs to collect diagnostic data as well as support programming by the physician. The ICD uses inductive telemetry and radio-frequency telemetry for the communication with the external devices such as a …


Implementation Of Physiologic Pressure Conditions In A Blood Vessel Mimic Bioreactor System, Kevin Mark Okarski Jul 2010

Implementation Of Physiologic Pressure Conditions In A Blood Vessel Mimic Bioreactor System, Kevin Mark Okarski

Master's Theses

ABSTRACT

Implementation of Physiologic Pressure Conditions in a Blood Vessel Mimic Bioreactor System

Kevin Mark Okarski

Tissue engineering has traditionally been pursued as a therapeutic science intended for restoring or replacing diseased or damaged biologic tissues or organs. Cal Poly’s Blood Vessel Mimic Laboratory is developing a novel application of tissue engineering as a tool for the preclinical evaluation of intravascular devices. The blood vessel mimic (BVM) system has been previously used to assess the tissue response to deployed stents, but under non-physiologic conditions. Since then, efforts have been made to improve the vessel and bioreactor’s ability to emulate in …


Finite Element Modeling Of Icd Lead Silicone Soft-Tips, Jose J. Lepe May 2010

Finite Element Modeling Of Icd Lead Silicone Soft-Tips, Jose J. Lepe

Master's Theses

Although highly underutilized by the medical device industry, Finite Element Analysis (FEA) in the development of new technologies is gaining popularity as regulatory bodies such as the Food and Drug Administration (FDA) begin to require additional proof of safety through scientific methods. Non-linear FEA allows engineers to realistically simulate the mechanical behavior of implants as seen in the in-vitro, or in some cases, the in-vivo configurations. The work presented in this report investigates how computational methods can be used to simulate the interaction of a St. Jude Medical silicone soft-tip as it passes through a Peel-Away Sheath (i.e. introducer). In …


Effects Of Reamer-Femoral Component Offset On Cement Mantle Penetration In Hip Resurfacing Arthroplasty, Mark Lloyd Paulick May 2010

Effects Of Reamer-Femoral Component Offset On Cement Mantle Penetration In Hip Resurfacing Arthroplasty, Mark Lloyd Paulick

Master's Theses

Hip resurfacing arthroplasty has changed the treatment of end stage arthritis without severe deformity for young, active adults. Presently, there are varying clinical approaches to implant design selection and cementation techniques. The purpose of this project is to determine what amount of reamer-femoral component offset allows for the best cement penetration into the femoral head.

Rapid prototyped femoral component models were produced with reamer femoral component offsets of 0.0 mm, 0.5 mm, and 1.0 mm. After implantation onto models of reamed femoral heads made from high-density open-cell reticulated carbon foam, cement penetration was assessed from cross-sections of the foam-implant unit. …


Biomechanical Comparison Of Wire Circlage And Rigid Plate Fixation For Median Sternotomy Closure In Human Cadaver Specimens, Mark Steven Wong Apr 2010

Biomechanical Comparison Of Wire Circlage And Rigid Plate Fixation For Median Sternotomy Closure In Human Cadaver Specimens, Mark Steven Wong

Master's Theses

Background:

Over 700,000 patients per year undergo open-heart surgery. Healing complication rates can be up to 5% of patients who undergo this procedure, with a morbidity rate of 50% if mediastinitis supervenes. A secure and rigid fixation of surgically divided sternum is critical to avoid healing complications. The purpose of this study was to compare the yield load, construct stiffness, ultimate load, displacement at ultimate load, and post-yield behavior of three sternotomy closure methods (Peristernal wires or Sternalock titanium plates) when stressed in each of three directions: lateral distraction, rostro-caudal (longitudinal) shear distraction, and anterior-posterior (transverse) shear in a cadaveric …


Merlin.Net Automation Of External Reports Verification Process, Gabriel John Wettlaufer Jan 2010

Merlin.Net Automation Of External Reports Verification Process, Gabriel John Wettlaufer

Master's Theses

Merlin.net Patient Care Network is a St. Jude Medical product that is used for remote patient management. The basic concept of Merlin.net is to allow the physician to view patient device follow-up information as well as general patient and device information on a web application. The Merlin.net system also interfaces with the patient and will send them notification if they miss a follow-up. All device information will be collected automatically while the patient is sleeping. This information is sent through a telephone line to a Merlin.net server to process a report package and display the collected information on the Merlin.net …